Add to Cart
96V 100A 10KW Off Grid Solar Inverter System
Off grid solar power system comprises of solar photovoltaic panels which are connected to the inverter. A photovoltaic panel generates energy by its system, which can be used in supply of electrical use to any appliance that are connected to the battery storage.
| Low frequency INVERTER 10KW OFF GRIDE SYSTEM | ||||
| NO. | Dscreption | Specification | QTY | |
| 1 | Low frequency INVERTER 12KW | 96v / 220v | SET | 1 |
| 2 | LDK 440W 42V BICFACIAL | A GRADE | PCS | 21 |
| 3 | 12v200ah | 530*248*265 | pc | 24 |
| 4 | combine box | 4input 1output | 1 | |
| 5 | CONTROLLER 100a | MPPT | 1 | |
| Totally | 48 | |||
| Name | QTY | L | W | H | CBM | weight | totally CBM | totally weight |
| Low frequency INVERTER 12KW | 1 | 620 | 376 | 850 | 0.20 | 105.00 | 0.20 | 105.00 |
| 12v200ah | 24 | 530 | 248 | 265 | 0.03 | 60.30 | 0.84 | 1447.20 |
| LDK 440W 42V BICFACIAL | 21 | 2200 | 35 | 1085 | 0.08 | 24.00 | 1.75 | 504.00 |
| combine box | 1 | 0 | 0 | 0 | 0.00 | 0.00 | 0.00 | 0.00 |
| TOTALLY: | 2.79 | 2056.20 | ||||||


| Model | 10KVA | 15KVA | 20KVA |
| Input Power | 220VAC (Standard) | ||
| Range of Input Voltage | Model 220V:154-264VAC ± 3V (Normal Mode) 185-264 ± 3V (UPS Model) | ||
| Input frequency | 50/60Hz±5% | ||
| Output Rated Power | 8000W | 12000W | 16000W |
| AC Output Voltage | The output voltage under AC is the same as the input voltage | ||
| AC output frequency | The output voltage frequency under AC is the same as the input frequency | ||
| Output Voltage under INV Mode | 220VAC±10% | ||
| Output frequency under INV mode | 50/60HZ±1% | ||
| Output Waveform under INV Mode | Pure Sine Wave | ||
| Battery type | External lead acid battery or water battery | ||
| Battery voltage | 96VDC / 192VDC | 96VDC / 192VDC | 192VDC |
| Battery Charging Voltage | 108DC / 216VDC | 108DC / 216VDC | 216VDC |
| Maximum AC Charging Current | 24A / 15A | 35A / 22A | 30A |
| Range of Battery Charging Voltage | 154-264VAC±3V | ||
| Transfer Time | ≤10ms(UPS mode)/≤20ms (INV mode) | ||
| Load peak ratio | (MAX)3:1 | ||
| Static power(W) | 120W | 250W | |
| Protection function | Input overcurrent air switch protection under AC mode | ||
| overload protection, short circuit protection, low voltage protection, (battery reverse connection insurance) under INV mode | |||
| Status display | Dot matrix fine screen plus LED display | ||
| Through the page key, can view the AC voltage, AC frequency, PV voltage, PV current, output voltage, output frequency, battery voltage, load current and other parameters. | |||
| LED display mains, charging status, inverter status, fault status | |||
| Audible alarm | Low battery protection-continuous beeping | ||
| Low battery protection-1 second beeping | |||
| Overload-continuous beeping | |||
| Overload less than 130%-1 second beeping and shutdown the output after 30 seconds; Overload more than 150%,shutdown the output after 300ms | |||
| Malfunction-continuous beeping | |||
| Working temperature | 0℃~40℃ | ||
| Storage temperature | —15℃~45℃ | ||
| Relative humidity | —10℃~90℃Non condensing | ||
| Accoustic Noise(db) | <45dB | ||
| Dimension(L*W*H)mm | 570*300*680 | ||
| Packing Dimension(L*W*H)mm | 620*376*850 | ||
| N.W (KG) | 69 | 89 | 99 |

| ELECTRICAL PARAMETERS@STC CM144H-430〜450 | |||||
| Max. Power Output Pmax (W) | 430 | 435 | 440 | 445 | 450 |
| Power Tolerance | 0-3% | 0 〜+3% | 0-+3% | 0~+3% | 0 〜+3% |
| Max. Power Voltage Vmp (V) | 41.27 | 41.47 | 41.67 | 41.87 | 42.06 |
| Max. Power Current Imp (A) | 10.42 | 1049 | 10.56 | 10.63 | 10.7 |
| Open Circuit Voltage Voc (V) | 49.65 | 49.85 | 50.05 | 50.26 | 50.43 |
| Short Circuit Current Isc (A) | ll.O8 | Il.l5 | H.22 | H.29 | H.36 |
| Module Efficiency (%) | 19.46 | 19.69 | 19.92 | 20.14 | 20.37 |
| STC (Standard Test Condition): Irradiance lOOOW/m2 , Cell Temperature 25OC, Air Mass 1.5 | |||||
| ELECTRICAL PARAMETERS@NMOT | |||||
| Max. Power Output Pmax (W) | 323 | 327 | 331 | 334 | 338 |
| Max. Power Voltage Vmp (V) | 38.45 | 38.64 | 38.82 | 39.01 | 39.19 |
| Max. Power Current Imp (A) | 8.4 | 8.46 | 8.52 | 8.57 | 8.63 |
| Open Circuit Voltage Voc (V) | 47.19 | 47.38 | 47.57 | 47.77 | 47.93 |
| Short Circuit Current Isc (A) | 8.93 | 8.99 | 9.05 | 9.1 | 9.16 |
| Nominal Module Operating Temperature (NMOT), Irradiance of 800W/m2, Spectrum AM 1.5, Ambient Temperature 20°C, Wind Speed Im/s | |||||
| TEMPERATURE COEFFICIENTS | |||||
| Temperature Coefficients of Pmp | -0.36%/°C | ||||
| Temperature Coefficients of Voc | -0.29%/°C | ||||
| Temperature Coefficients of Isc | +0.048%/°C | ||||
| MECHANICAL PARAMETERS | |||||
| Cell Type | Mono 166 X83mm | ||||
| Number of Cells | I44pcs (2X (6X12)) | ||||
| Dimensions (L^W*H) | 2l08Xl048X35mm | ||||
| Weight | 25kg | ||||
| Frame | Anodized Aluminum | ||||
| Junction Box | IP67, 3 bypass diodes | ||||
| Cable, Length | 4mm2, 350mm | ||||









Product Paramenters
| Nominal Voltage | 12V | |
| Nominal Capacity (10HR) | 200AH | |
| Dimension | Length | 522 ±3mm (20.55 inches) |
| Width | 240 ±2mm (9.45 inches) | |
| Container Height | 221 ±2mm (8.70 inches) | |
| Total Height (withTerminal) | 226 ±2mm (8.89 inches) | |
| Approx Weight | Approx 55.0 kg (121lbs) | |
| Terminal | T11 | |
| Container Material | ABS | |
| Rated Capacity | 209.1 AH/10.4A | (20hr ,1.80V/cell,25℃/77℉) |
| 200.0 AH/20.0A | (10hr,1.80V/cell,25℃/77℉) | |
| 173.0 A H/34.6A | (5hr,1.75V/cell,25℃/77℉) | |
| 157.2 AH/52.4A | (3hr,1.75V/cell,25℃/77℉) | |
| 122.8 AH/122.8A | (1hr,1.60V/cell,25℃/77℉) | |
| Max. Discharge Current | 1800A (5s) | |
| Internal Resistance | Approx 3.4mΩ | |
| Operating Temp.Range | Discharge : -30~50℃ (5~122℉) | |
| Charge : 0~40℃ (32~104℉) | ||
| Aircraft signal Storage : -30~40℃ (5~104℉) | ||
| Nominal Operating Temp. Range | 25 ±3℃ (77 ±5℉ ) | |
| Cycle Use | Initial Charging Current less than 60.0A.Voltage Communication power supply 14.4V~15.0V at 25℃(77℉)Temp. Coefficient -30mV/℃ | |
| Standby Use | No limit on Initial Charging Current Voltage Auto controlsystem 13.5V~13.8V at 25℃(77℉)Temp. Coefficient -20mV/℃ | |
| Capacity affectedby Temperature | 40℃ (104 ℉)103% | |
| 25℃ ( 77 ℉ )100% | ||
| 0℃ ( 32℉ ) 86% | ||
| Self Discharge | GEL series batteries may be stored for up to 6 months at 25℃(77℉) and battery should be recharge before use . For higher temperatures the time interval will be shorter. | |
| Warranty | |
| FULL SETS SYSTEM | 1years |
| Solar | 12years products on materials 25years liner power performance |
| Inverter | 1year |
| GEL battery | 1year |
| LI battery | 3years |
| GRAPHENE battery | 5years |