Model | 1000VA | 1500VA | 2000VA | 3000VA | 5000VA |
Input Voltage(DC) | 12V/24V | 12V/24V | 12V/24V | 24V/48V | 24V/48V |
Nominal Voltage | 220VAC(Standard) | ||||
Voltage Range | 154-264VAC ±3(Normal Mode);185-264VAC±3V(UPS Model);175-285VAC±3V(AVR Model); | ||||
Frequency | 50/60Hz±5% | ||||
Power Factor | 0.8 | ||||
Rated Power | 800W | 1200W | 1600W | 2400W | 4000W |
Output Voltage(AC) | The output voltage under AC is the same as the input voltage | ||||
220VAC±10%(With AVR function) | |||||
Output Frequency (AC) | The output voltage frequency under AC is the same as the input frequency | ||||
Output Voltage(DC) | 220VAC±3% | ||||
Output Frequency (DC) | 50/60Hz±1% | ||||
Waveform | Pure Sine Wave | ||||
Battery Type | External lead acid battery or water battery | ||||
Battery voltage | 12/24VDC | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC |
Battery Charging Voltage | 13.75/27VDC | 13.75/27VDC | 13.75/27VDC | 27/54VDC | 27/54VDC |
Maximum pv array power | 12V:800W / 24V:1600W/ 48V:3200W | ||||
PV Input Voltage Range (PWM Controller) | 12V:MPPT 15V-150VDC / PWM 15V-30VDC | ||||
24V:MPPT 30V-150VDC / PWM 30V-60VDC | |||||
48V:MPPT 60V-150VDC / PWM 60V-105VDC | |||||
Maximum photovoltaic display open circuit voltage | 12V:MPPT 150VDC / PWM 30VDC | ||||
24V:MPPT 150VDC / PWM 60VDC | |||||
48V:MPPT 150VDC / PWM 105VDC | |||||
Maximum solar charging current | 60A | ||||
Maximum AC charging current | 15A/8A | 30A/15A | 40A/20A | 30A/15A | 42A/21A |
Battery charging voltage range | 154-280VAC | ||||
Transfer Time | ≤10ms(UPS mode)/≤20ms (INV mode) | ||||
Load peak ratio | (MAX)3:1 | ||||
Static power(W) | 5W | 11.5W | 13W | 15W | 20W |
Protections | Power supply: Input overcurrent protector | ||||
LCD indicator status | AC input voltage, AC input frequency, PV voltage, PV current , Output Voltage, Output Frequency, | ||||
Battery voltage, Load current etc. | |||||
Audible alarm | Low battery protection-continuous beeping | ||||
Low battery protection-1 second beeping | |||||
Overload-continuous beeping | |||||
Overload less than 130%-1 second beeping and shutdown the output after 30 seconds; | |||||
Overload more than 150%,shutdown the outputafter 300ms | |||||
Malfunction-continuous beeping | |||||
Temperature | 0-40℃ | ||||
Humidity | —10℃~90℃ Non condensing | ||||
Accoustic Noise(db) | <45dB | ||||
Dimension(L*W*H)mm | 512*320*136 | ||||
Weight (kg) | 11.5 | 12.5 | 15 | 16.8 | 21.5 |
Packaging Dimension(L*W*H)mm | 650*440*250 | ||||
PackagingWeight (kg) | 14.5 | 15.6 | 18.2 | 20 | 25 |
Warranty:
Warranty | |
FULL SETS SYSTEM | 1years |
Solar | 12years products on materials |
Inverter | High frequency 1year |
GEL battery | 1year |
LI battery | 3years |
GRAPHENE battery | 5years |
Payment iterm:
|
T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. |
FOB | |||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | ||
CIF | |||
L/C | For the amount of one shipment above 50,000 usd, L/C at sight is acceptable. | ||
West Union | | ||
Paypal |